{"id":7,"date":"2026-06-30T12:28:58","date_gmt":"2026-06-30T12:28:58","guid":{"rendered":""},"modified":"2026-06-30T12:50:58","modified_gmt":"2026-06-30T12:50:58","slug":"home","status":"publish","type":"page","link":"https:\/\/cylink.co.il\/","title":{"rendered":"Home"},"content":{"rendered":"<section class=\"hero\">\n<div class=\"hero-inner\">\n<div class=\"hero-copy\">\n<p class=\"eyebrow\">Secure OT to cloud connectivity<\/p>\n<h1>CyLink<\/h1>\n<p class=\"lead\">Connect critical infrastructure to cloud monitoring, control rooms and operational platforms without exposing the OT network.<\/p>\n<div class=\"hero-actions\">\n                <a class=\"button\" href=\"#products\">View Products<\/a><br \/>\n                <a class=\"button secondary\" href=\"#platform\">How It Works<\/a>\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n<section id=\"platform\" class=\"section\">\n<div class=\"wrap\">\n<div class=\"section-head\">\n<p class=\"eyebrow\">The OT cloud paradox<\/p>\n<h2>More visibility without opening a path back into the field.<\/h2>\n<p>Operations teams need real-time data, predictive maintenance and remote awareness. Traditional routers, inbound VPNs and exposed ports increase cyber risk. CyLink is designed around outbound-only communication, cryptographic identity and hardened edge operation.<\/p>\n<\/p><\/div>\n<div class=\"grid\">\n<article class=\"card\">\n<h3>Outbound-only architecture<\/h3>\n<p>Communication is initiated by the device toward predefined authorized servers. No inbound ports or inbound VPN are required.<\/p>\n<\/article>\n<article class=\"card\">\n<h3>Mutual authentication<\/h3>\n<p>mTLS, device identity, allow-listed servers and encrypted transport verify every communicating party.<\/p>\n<\/article>\n<article class=\"card\">\n<h3>Data-agnostic transport<\/h3>\n<p>CyLink can pass industrial data as-is without interpreting payloads, converting protocols or changing PLC logic.<\/p>\n<\/article><\/div>\n<\/p><\/div>\n<\/section>\n<section id=\"products\" class=\"section alt\">\n<div class=\"wrap\">\n<div class=\"section-head\">\n<p class=\"eyebrow\">Product family<\/p>\n<h2>Three products for secure OT visibility and control.<\/h2>\n<\/p><\/div>\n<article class=\"product\">\n<div>\n<p class=\"eyebrow\">Product 01<\/p>\n<h3>CyLink HMI<\/h3>\n<p class=\"lead\">A remote monitoring and control platform for live Modbus data, alarms, dashboards and safe control actions from a web app.<\/p>\n<div class=\"pill-row\">\n                    <span class=\"pill\">Live dashboards<\/span><br \/>\n                    <span class=\"pill\">Alarm notifications<\/span><br \/>\n                    <span class=\"pill\">Role-based access<\/span><br \/>\n                    <span class=\"pill\">Safe writable elements<\/span>\n                <\/div>\n<\/p><\/div>\n<div class=\"product-media\">\n                <img decoding=\"async\" src=\"\/wp-content\/themes\/cylink-marketing\/assets\/marketing.png\" alt=\"CyLink marketing presentation cover\">\n            <\/div>\n<\/article>\n<article class=\"product\">\n<div>\n<p class=\"eyebrow\">Product 02<\/p>\n<h3>CyLink Forensics<\/h3>\n<p class=\"lead\">An Industrial Communication Recorder for continuous recording, long-term evidence preservation, replay and investigation of OT communications.<\/p>\n<div class=\"pill-row\">\n                    <span class=\"pill\">Serial and IP capture<\/span><br \/>\n                    <span class=\"pill\">Modbus RTU reconstruction<\/span><br \/>\n                    <span class=\"pill\">Evidence integrity<\/span><br \/>\n                    <span class=\"pill\">Incident replay<\/span>\n                <\/div>\n<\/p><\/div>\n<div class=\"card\">\n<h3>Industrial digital flight recorder<\/h3>\n<p>Designed to capture every industrial communication, preserve it as tamper-evident evidence and help teams reconstruct operational events after an incident.<\/p>\n<\/p><\/div>\n<\/article>\n<article class=\"product\">\n<div>\n<p class=\"eyebrow\">Product 03<\/p>\n<h3>CyLink Modbus RTU Data Diode<\/h3>\n<p class=\"lead\">Secure one-way telemetry extraction from protected OT networks with no inbound communication path from cloud or modem.<\/p>\n<div class=\"pill-row\">\n                    <span class=\"pill\">One-way telemetry<\/span><br \/>\n                    <span class=\"pill\">No physical return path<\/span><br \/>\n                    <span class=\"pill\">RS-485 \/ Modbus RTU<\/span><br \/>\n                    <span class=\"pill\">Critical infrastructure<\/span>\n                <\/div>\n<\/p><\/div>\n<div class=\"product-media\">\n                <img decoding=\"async\" src=\"\/wp-content\/themes\/cylink-marketing\/assets\/data-diode.png\" alt=\"CyLink Modbus RTU Data Diode presentation cover\">\n            <\/div>\n<\/article><\/div>\n<\/section>\n<section id=\"industries\" class=\"section\">\n<div class=\"wrap split\">\n<div class=\"section-head\">\n<p class=\"eyebrow\">Where CyLink fits<\/p>\n<h2>Built for infrastructure that cannot afford downtime.<\/h2>\n<p>CyLink supports industrial teams moving from reactive maintenance to continuous visibility, predictive maintenance and data-driven operations.<\/p>\n<\/p><\/div>\n<div class=\"feature-list\">\n<div class=\"feature\">\n                <strong>Water and wastewater<\/strong><br \/>\n                <span>Pumping stations, remote assets, tanks and field controllers.<\/span>\n            <\/div>\n<div class=\"feature\">\n                <strong>Energy and BESS<\/strong><br \/>\n                <span>Distributed energy systems, storage sites and critical remote equipment.<\/span>\n            <\/div>\n<div class=\"feature\">\n                <strong>Industrial facilities<\/strong><br \/>\n                <span>Factories, production lines, Modbus devices and maintenance workflows.<\/span>\n            <\/div>\n<div class=\"feature\">\n                <strong>Defense-oriented deployments<\/strong><br \/>\n                <span>Mobile systems, perimeter assets and operational equipment requiring high assurance connectivity.<\/span>\n            <\/div>\n<\/p><\/div>\n<\/p><\/div>\n<\/section>\n<section class=\"section alt\">\n<div class=\"wrap\">\n<div class=\"grid\">\n<article class=\"card\">\n<h3>Industrial design<\/h3>\n<ul>\n<li>9-24 VDC input<\/li>\n<li>Surge, transient, reverse polarity and brownout protection<\/li>\n<li>Continuous 24\/7 operation<\/li>\n<li>Extended industrial temperature range<\/li>\n<\/ul>\n<\/article>\n<article class=\"card\">\n<h3>Secure supply chain<\/h3>\n<ul>\n<li>Developed in Israel<\/li>\n<li>Western supply chain focus<\/li>\n<li>No Chinese-source communication modules<\/li>\n<li>Traceability for critical components<\/li>\n<\/ul>\n<\/article>\n<article class=\"card\">\n<h3>Field interfaces<\/h3>\n<ul>\n<li>RS-485<\/li>\n<li>Modbus RTU, ASCII, TCP and RTU over TCP<\/li>\n<li>CAN 2.0A \/ 2.0B, J1939 and CANopen<\/li>\n<li>Digital, analog and custom expansion modules<\/li>\n<\/ul>\n<\/article><\/div>\n<\/p><\/div>\n<\/section>\n<section id=\"contact\" class=\"section\">\n<div class=\"wrap\">\n<div class=\"cta\">\n<p class=\"eyebrow\">Rotal Innovative Technologies<\/p>\n<h2>Turn field equipment into connected, intelligent and managed infrastructure.<\/h2>\n<p>Use CyLink when the business needs cloud visibility and operational continuity, but the OT network must remain protected from inbound exposure.<\/p>\n<p>            <a class=\"button\" href=\"mailto:info@rit.co.il\">Contact RIT<\/a>\n        <\/div>\n<\/p><\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"<p>Secure OT to cloud connectivity CyLink Connect critical infrastructure to cloud monitoring, control rooms and operational platforms without exposing the OT network. View Products How It Works The [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-7","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/cylink.co.il\/index.php?rest_route=\/wp\/v2\/pages\/7","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cylink.co.il\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cylink.co.il\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cylink.co.il\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cylink.co.il\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=7"}],"version-history":[{"count":1,"href":"https:\/\/cylink.co.il\/index.php?rest_route=\/wp\/v2\/pages\/7\/revisions"}],"predecessor-version":[{"id":11,"href":"https:\/\/cylink.co.il\/index.php?rest_route=\/wp\/v2\/pages\/7\/revisions\/11"}],"wp:attachment":[{"href":"https:\/\/cylink.co.il\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=7"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}